MASK STANDARDS

STANDARD

APPROVING INSTITUTION CLASSIFICATION (According to retention criteria) USAGE TYPE/LIFE (cost) PERCENTAGE OF OXYGEN IN THE BLOOD FILTERING DIRECTION RESPIRATORY RESISTANCE
INHALING RESISTANCE LIMITS (30 liters/min) EXHALING RESISTANCE LIMITS (160 liters/min)
TS EN 14683 (UGMA Filtered Valveless Medical Face Mask) The Ministry of Health Microorganism retention 99.9 % Replaceable filter 10-70 hours (for health workers 10 hours) %97 No valve, Double-sided Filtering

max 6Pa

TS EN 149 + A1 (N95 / N99) Ministry of Labor FFP1: min 80% dust holder filter
FFP2: min 95% dust holder filter
FFP3: min 99% dust holder filter
Disposable 5-10 hours %60 With valve-one-sided filtering (in the direction of inhaling) FFP1: max 60 Pa
FFP2: max 70 Pa
FFP3: max 100 Pa
FFP1: max 300 Pa
FFP2: max 300 Pa
FFP3: max 300 Pa
TS 14683 AC (SURGICAL MASK) The Ministry of Health Type I: min 95% Microorganism retention
Type II: min 98% Microorganism retention
Type II R: > 99% Microorganism retention
Disposable 3-6 hours %92 No valve, Double-sided Filtering Type I: max 40Pa
Type II: max 70Pa
Type II R: max 60Pa

TS EN 141

Ministry of Labour A: Boiling temperature 65 C ... high organic gas and vapor
Color Code:
Brown
B: Organic gases and vapors (except CO)
Color Code Gray
E: Sulfur dioxide and other acidic gases and vapors Color Code: Yellow
K: Ammonia and organic ammonia derivatives
Color Code: Green P1/P2/P3 Particle filters
Color Code: White
Hg: Mercury
Color Code: Red
Replaceable Filter 0.25-4 hours %60 With valve-one-sided filtering (in the direction of inhaling) Outside the Working Area

Outside the Working Area